Do you have an example for Photovoltaic generators and battery storage systems?

Power Equipment Models

In the attached example (PhotovBattery.pfd ) two explicit modelling approaches are shown. The models we recommend for PowerFactory simulations are very similar to each other. The PV generator consists of a DC current source, connected to the AC system by a PWM converter. The battery storage system consists of a DC voltage source using as well a PWM converter. Consider the different control mode of the PWM converter in each application.

It is also possible to model the battery via a single network element, the Battery-Storage element. The photovoltaic system can also be modelled as a single network element. In this case chose the PV-System element (ElmPvsys).